<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>10051</ErrorNumber>
<ErrorFamily>Hardware</ErrorFamily>
<ErrorMessage>
HARDWARE: DPE failure - dpath control write = &lt;hex data&gt;, read = &lt;hex data&gt;
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The DPE's datapath control register is tested at the beginning of every plot.  This message reports that the
contents of this register just before plotting were different than what was written to the register during plot
initialization.  Although this test was originally implemented to find a possible DPE bug, it now much
more likely indicates a firmware bug, where the dpath control register is being setup a plot time with
different parameters from plot initialization.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
Firmware bug
</Cause>
<Cause>
DPE is faulty
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:30 2008 PST
</Updated>
<Links>
</Links>
</Error>